상세 컨텐츠

본문 제목

Easy Lift Mk2 Garage Door Motor Manual

카테고리 없음

by obacacab1981 2020. 2. 29. 10:13

본문

  1. Easylift Mark 2 Price

With a highly trained staff and the equipment to do the job safely and efficiently, Easy Lift Doors has been successfully serving industries for over 40 years. Our expert work crews operate across Southern Ontario. From sales to installations, maintenance and repairs, we are committed to providing high quality products, quick and reliable service and competitive pricing. We work for various sectors of the economy including: agricultural, commercial, industrial, institutional, food production and residential overhead door applications. There may be a number of reasons why your overhead door does that. A built-in safety feature makes the electric opener open the door back up if something is out of the normal to prevent damage or any threats to safety. There are several things you can do to troubleshoot the problem.

Check that the threshold of the overhead door is clear. The opener may sense if there is something blocking it even slightly. Take a closer look at the photo safety eyes or photo-cells located at the bottom of the tracks. Sometimes if they get hit or misaligned and the infrared beam between them gets disrupted the opener will believe that something is blocking the door.

If the small green or red (amber) light on the safety eye is not turned on, it may be a sign of the safety eyes being misaligned and the beam not getting reflected from the other unit. In this case try aligning them with each other until the lights come back on, try then to close the door normally. Often the safety eyes may be fine but the wires connecting them to the opener may be damaged, cut or short-circuited by touching another surface. You can try moving the wire around carefully with your fingers to see if the lights on the safety eyes blink or come back on when you move the wire. It could be as simple as a cobweb or fly etc interfering with the beam, try to make sure there is no obstruction that may cause the two eyes not to see each other. The regular travel distance may be hindered. This can sometimes happen if the tracks or hardware of the overhead door get hit or twisted out of place.

The opener can believe there is something blocking the overhead door if it is forced to stop before it has moved the programmed travel distance.Travel limits may be slightly off in the openers limits switch. The limits control the exact spots where the overhead door stops when it is raised or lowered. On residential garage door openers, the limits can be adjusted by turning the limit screws with a flat-head screwdriver. The limit screws are usually located on the side of your opener.

Easy Lift Mk2 Garage Door Motor Manual

On larger commercial openers, setting their limits is a bit more complicated. On some openers the limits can be adjusted by pushing down the brake plate and turning the two white limit cogs to the desired spot on the limit shaft. You will need to open the opener cover and locate the limit shaft in order to do this. It is however highly recommended that a trained service technician does this work as contacting any of the circuitry may cause further expensive damage. There is also a safety risk of electrocution. The logic board may be malfunctioning. Like any electrical devices the logic board, the central brain in the opener that controls the operation of the overhead door, can get worn out with time.

It may also be affected by voltage spikes in the electrical grid or if the proper voltage does not pass through to the opener. Other signs of a faulty logic board may be that the overhead door opens or closes by itself without explanation, even though the door otherwise operates normally.If your overhead door is still not working properly or you feel uncomfortable troubleshooting or working with your overhead door and opener yourself, please don’t hesitate to call us.

Easy Lift Doors expert technicians are more than glad to help and will promptly get your overhead door working properly again. Yes, you can paint your door but first take into consideration that the warranty will be null and void once you paint them and if damage is done to your door and a panel needs to be replaced you will likely need to repaint the entire door due to the UV rays fading the paint you used. This is due to not being baked on as it is in the factory. Upon saying this your residential and commercial overhead doors can be painted with any high quality exterior latex paint. Do not use an oil based paint. Please consult your paint store for which exterior latex paint is recommended for the surface on your overhead door.Painting instructions: Remove the weather stripping from the sides & top. Rub the exterior with a Scotch-brite fiber pot-scubber to dull the surface a bit.

You can buy the pot-scubber at Loblaws, Zehrs, No-Frills etc. Do NOT use steel wool. Then wash with a diluted trisodium phosphate (TSP) solution (Home hardware or CTC); rinse and let dry. Then apply a good acrylic latex paint in the shade when the door is cool.

If you paint in the sun when the door is hot, the paint dries almost instantly. It doesn’t have a chance to “level” between brush or roller strokes and bubbles may harden in place. Paint the joint between the top of one section & the bottom of the one above it, with a very thin coat, allowing it to dry before the sections contact each other. Lift the door gradually to get access to this joint, as it goes around the curve at the top of the door. Re-attach the weather-stripping after a day, using the same pieces lined up with the same screw holes.

If the weather-stripping is attached too soon, it will stick to the soft paint and may peel off when the door is opened. Yes, Easy Lift Doors can replace sections (panels) of your damaged garage door whether they are at the bottom, middle or top of your door. We can replace sections for any model of garage door providing we can identify the make and model of the existing door.

When replacing only a damaged section of an old door there may be a difference in color and sheen between new and old sections. The difference can be lessened by painting the sections or waxing the undamaged sections with car wax to match the shine between the sections. If the damage is more extensive and you need to replace more than a couple of sections, it may be cheaper to get the entire door replaced. Inquire about our replacement sections and we can give you a free quote and discuss options. There may be a number of reasons why your overhead door does that.

A built-in safety feature makes the electric opener open the door back up if something is out of the normal to prevent damage or any threats to safety. There are several things you can do to troubleshoot the problem. Check that the threshold of the overhead door is clear. The opener may sense if there is something blocking it even slightly. Take a closer look at the photo safety eyes or photo-cells located at the bottom of the tracks. Sometimes if they get hit or misaligned and the infrared beam between them gets disrupted the opener will believe that something is blocking the door.

If the small green or red (amber) light on the safety eye is not turned on, it may be a sign of the safety eyes being misaligned and the beam not getting reflected from the other unit. In this case try aligning them with each other until the lights come back on, try then to close the door normally. Often the safety eyes may be fine but the wires connecting them to the opener may be damaged, cut or short-circuited by touching another surface.

You can try moving the wire around carefully with your fingers to see if the lights on the safety eyes blink or come back on when you move the wire. It could be as simple as a cobweb or fly etc interfering with the beam, try to make sure there is no obstruction that may cause the two eyes not to see each other. The regular travel distance may be hindered. This can sometimes happen if the tracks or hardware of the overhead door get hit or twisted out of place. The opener can believe there is something blocking the overhead door if it is forced to stop before it has moved the programmed travel distance.Travel limits may be slightly off in the openers limits switch. The limits control the exact spots where the overhead door stops when it is raised or lowered.

On residential garage door openers, the limits can be adjusted by turning the limit screws with a flat-head screwdriver. The limit screws are usually located on the side of your opener. On larger commercial openers, setting their limits is a bit more complicated.

On some openers the limits can be adjusted by pushing down the brake plate and turning the two white limit cogs to the desired spot on the limit shaft. You will need to open the opener cover and locate the limit shaft in order to do this. It is however highly recommended that a trained service technician does this work as contacting any of the circuitry may cause further expensive damage. There is also a safety risk of electrocution. The logic board may be malfunctioning. Like any electrical devices the logic board, the central brain in the opener that controls the operation of the overhead door, can get worn out with time.

Easylift Mark 2 Price

It may also be affected by voltage spikes in the electrical grid or if the proper voltage does not pass through to the opener. Other signs of a faulty logic board may be that the overhead door opens or closes by itself without explanation, even though the door otherwise operates normally.If your overhead door is still not working properly or you feel uncomfortable troubleshooting or working with your overhead door and opener yourself, please don’t hesitate to call us.

Easy Lift Doors expert technicians are more than glad to help and will promptly get your overhead door working properly again. Yes, Easy Lift Doors can replace sections (panels) of your damaged garage door whether they are at the bottom, middle or top of your door. We can replace sections for any model of garage door providing we can identify the make and model of the existing door. When replacing only a damaged section of an old door there may be a difference in color and sheen between new and old sections. The difference can be lessened by painting the sections or waxing the undamaged sections with car wax to match the shine between the sections.

If the damage is more extensive and you need to replace more than a couple of sections, it may be cheaper to get the entire door replaced. Inquire about our replacement sections and we can give you a free quote and discuss options. Yes, Easy Lift Doors can replace sections (panels) of your damaged overhead door whether they are at the bottom, middle or top of your door. We can replace sections for any type of agricultural, commercial, industrial or residential overhead door. When replacing only a damaged section of an old door there may be a difference in color and sheen between new and old sections. The difference can be lessened by painting the sections or waxing the undamaged sections with car wax to match the shine between the sections.

If the damage is more extensive and you need to replace more than a couple of sections, it may be cheaper to get the entire door replaced. Inquire about our replacement sections and we can give you a free quote.

Steel-Line Garage & Roller Garage Door Operator Installation ManualsSteel-line is the roller garage door operation of UK based Cardale garage doors. Steel Line garage door operators have been changed several times over the years starting in 1997 with the Unilift and from 2007 the Australian made ATA Slim Drive Easy Roller.Garage door opener manuals will provide you with lots of information, including installation, operating and remote control programming instructions.Below are links to available Steel Line garage opener and operator manuals.Please note some of the PDF manuals are very large and may take a while to open.